Roth shunt 3-way with thermostatic valve


The shunt comes with a Wilo Para pump 15-130/6. The pump and shunt are designed for systems of up to 240 m², however, depending on the current heat loss and choice of pipe dimensions.

The shunt is designed to be able to collect the water from the heat source itself, so that in some types of systems the primary pump can be dispensed with completely or alternatively only has to provide a very small primary pressure. It is possible to regulate the flow temperature in the range of 25-60°C.

The thermostat can be locked. The shunt is left-hung, but can easily be flipped and converted to right-hung. The shunt comes complete with thermometer, gaskets, thermostat and pump.
 

Downloads


Technical data

Roth shunt 3-way with thermostatic valve

UK NO. 7466210218
Max. operating temperatureMax. 80°C on prim. side
Max. differential pressure50 kPa
Max. operating pressure6 bar
Wilo PumpPARA MS15/6 - 43/SC-12
Pump output3 - 43W
Regulation range20-60°C +/- 5°C
Primary side connectionEURO ¾” external
Union for manifold1” internal
MaterialBrass CW614
GasketEPDM
MediumWater containing up to 50%
glycol
Electrical connection230V with earthing

 

Roth insulation for Roth shunt

Roth insulation is easy and practical to put on the Roth shunt and ensures a nice finish of the underfloor heating installation. Roth insulation has cutting lines that make it easy to customize it if you need to shorten it.

Roth insulation is prepared for installations with the pump mounted on the left, but can easily be changed if the pump is desired on the right side. For larger plants with shunter, you can extend with our universal insulation jacket for distributor pipes.

Roth insulation for Roth shunt with distributor up to 3 branches, plumbing no. 401973.892. Roth insulation for Roth ShuntUnit with up to 6 branches, plumbing no. 401973.891.

  1. Perfectly suited for shunt with both thermostatic valve and road compensation plant
  2. Can be easily cut with a knife when using the cutting lines
  3. Meets the requirements of DS 452
  4. The pump can be mounted both on the left and right
  5. Strong material that does not crack
  6. Contains flame retardant material
  7. Nice finish on the underfloor heating installation
  8. Delivered fully assembled - ready for installation

For more informations?